Containment Solutions, Inc., (CSI)

Containment Solutions, Inc., (CSI)

- In Situ Retrofit For Fiberglass Tanks - Biofuel Tank Upgrade

From

0

The BTU, Biofuel Tank Upgrade, is a cost-effective solution for upgrading existing fiberglass single-wall and double-wall tanks to meet new regulations. Many of the earliest generation fiberglass tanks were not tested nor were they warranted for either biodiesel or ethanol blends exceeding 10%. Upgrade your tank to full compatibility with green fuel blends like E15, E85 up to E100.

The BTU can be applied in combination with typical...

The BTU can be applied in combination with typical tank upgrades like sumps and collars or as a stand-alone service. Unlike conventional tank lining methods, the BTU upgrade is completed by CSI technicians who are experts in fiberglass tank manufacturing techniques.

In most cases the candidates for the BTU are older tanks. All Containment Solutions single-wall and double-wall storage tanks are compatible with ethanol blends up to E100 and biodiesel blends up to B100.

With the trend toward cleaner burning biofuels, re...

With the trend toward cleaner burning biofuels, retail marketers are evaluating their UST systems to determine if upgrades are necessary to meet current regulations. Many of the earliest generation fiberglass tanks were not tested nor were they warranted for either biodiesel or ethanol blends exceeding 10%.

Containment Solutions’ Biofuel Tank Upgrade (BTU) is a cost-effective solution to upgrade your existing single-wall fiberglass tank. Ethanol blends up to and including E100, and biodiesel blends up to B100 are all compatible with the BTU upgrade from Containment Solutions Inc. (CSI).

Unlike conventional tank lining methods, the BTU upgrade is completed by CSI technicians who are experts in fi berglass tank manufacturing techniques. Our nationwide network of technicians always have the latest certifications in OSHA confined space entry and HAZMAT training.

BTU Advantages:

  • 10 - Year Limited Warranty
  • Eliminates costly tank replacement and downtime
  • Complies with API 1631 sections on FRP tanks
  • Complies with FTPI Recommended Practice T-95-02 Including Change of Contents
    Section 6
  • Utilizes materials currently listed for the storage of petroleum products, alcohol’s and alcohol gasoline mixtures in UL1316
  • Compatible with BioDiesel as defi ned by ASTM D 6751
  • Complies with NLPA Standard 631

Standards:

API 1631
Complies with American Petroleum Institute Standard
Interior Lining and Periodic Inspection of Underground Storage Tanks (see sections on FRP tanks)

FTPI T-95-02
Complies with Fiberglass Tank and Pipe Institute’s Recommended Practice
Remanufacturing of Fiberglass Reinforced Plastic (FRP) Underground Storage Tanks (including Change of Contents Section 6)

UL 1316
Utilizes materials currently listed for the storage of petroleum products, alcohol’s and alcohol gasoline mixtures in Underwriters Laboratories Standard
Glass-Fiber-Reinforced Plastic Underground Tanks for Petroleum Products, Alcohols, and Alcohol-Gasoline Mixtures

ASTM D 6751
Compatible with BioDiesel as defined by the American Society for Testing and Materials Standard
Specification for Biodiesel Fuel Blend Stock (B100) for Middle Distillate Fuels

NLPA 631
Complies with National Leak Prevention Association NLPA Standard
Entry, Cleaning, Interior Inspection, Repair, and Lining of Underground Tanks

Customer reviews

No reviews were found for CSI BTU - In Situ Retrofit For Fiberglass Tanks - Biofuel Tank Upgrade. Be the first to review!