Only show results in USA? Ok

Aereon Flaring Equipment & Supplies

18 equipment items found
  • based in ITALY

    We design Enclosed ground flares when waste gases are requested to be flared in an enclosed stack, with reduced flame visibility, minimal heat and noise, emissions sampling, ease, and smokeless combustion, in sensitive areas. The stack is internally refractory lined, designed for low and medium flows, has high destruction efficiencies relative to an open ...

  • based in ITALY

    The Ghost series of enclosed biogas flares is a simple and cost effective combustion solution for a variety of applications where a hidden flame is required. The superior design, high quality stainless steel construction and unmatched versatility make the Ghost Series Enclosed Flares an exceptional choice for emissions control within the biogas and wastewater ...

  • based in ITALY

    To dispose of heavy waste gases, which have a greater tendency to smoke, in a smokeless manner, we provide three different design options, depending on customer requirements. Air Assisted Flares, which utilize forced air from blower(s) to provide assist air for combustion and promotes additional air entrain from the ambient due to the relatively high exit speed of the streams. ...

  • based in ITALY

    Utility flares (DU series) are one of the most common flare designs use for applications with no smokeless burning requirements. They are also utilized in applications where smokeless flaring can be achieved without the use of an additional assist ...

  • based in ITALY

    The Pit Flare (or “Burn Pit”) is usually constructed of an excavation lined with a non-combustible lining of rock or refractory material. Often coupled with a pit liner, our pit flares can be a cost-effective combustion option for an environmentally conscious user. ...

  • based in ITALY

    AEREON's Inferno Series Gas-assisted flares are flares that use an additional source of high pressure gas at the flare tip to mix with the waste gas and create additional turbulence to ensure adequate mixing with air, which in turn provides for smokeless combustion. The waste gas is further distributed at the flare tip through ...

  • based in ITALY

    AEREON's Cyclone Series Air-assisted flares are comprised of two risers (waste gas and air) and a blower system that provides supplemental combustion air. Air is fed by the blower into the air riser, to eventually combine with the process gas, which passes through its own secondary riser and is distributed at the flare tip through a proprietary AEREON Starfire ...

  • based in ITALY

    Our Titan Demountable Flares, also named demountable derricks, are derrick-supported flares with three, or four leg configurations and overall heights of up to 200 meters. Designed to accommodate several risers/tips on the same derrick structure. Each flare tip has its own set of pilots. ...

  • based in ITALY

    AEREON's Momentum Series of non-assist flares provide smokeless performance without the need of additional air-blowers or assist gas for both high pressure and low pressure gas streams. Leveraging the increased momentum of gas that is passed through a simple nozzle or restricted opening, the waste gas intimately mixes with the ambient air and provides for smokeless operation ...

  • based in ITALY

    Our Peacock Oil Burners are designed to flare liquid hydrocarbons without liquid fallout or soot formation. These burners provide excellent service for well testing operations. When only oil is flared, a high-pressure air or gas source is required to provide additional mechanical atomization to ensure the mixture is a fine mist when it exits the burner nozzle ...

  • based in ITALY

    Whenever a process requires that entrained droplets be removed from a vapor stream, a knockout drum should be integrated into the system. Condensation can occur when hot process gases cool considerably in the flare gas header and riser, and some gases also go to dew point at ambient temperatures and pressures and can therefore generate liquids. These droplets must be removed in ...

  • based in ITALY

    This intruding air is drawn out of the boundary layer and into the exiting purge gas flow column, thus purging the flare tip. This technology is a standard on various ...

  • based in ITALY

    The FFG is easily adaptable to any pilot system which incorporates an ignition tube and may be installed up to 1 mile (1600m) from the base of the flare stack. Both automatic and manual modes are ...

  • based in ITALY

    Hydrocarbon vapors may be destroyed in a flare, combustor or a thermal oxidizer. For many applications, a simple vapor combustor can be successfully used as a safe and economical method of controlling vapors from the handling, storage, or loading of volatile liquid hydrocarbons or other compounds when recovery of the vapors is not a viable ...

  • based in ITALY

    The Model 245 Fuel Efficient Flare Pilot is a high alloy, stainless steel pilot composed of fuel gas line, ignition line, inspirator and optional thermocouple. The pilot head assembly includes a 310 stainless steel flame retention nozzle and wind shroud for extended service life capable of sustaining a stable flame in winds of up to 150 mph. ...

  • based in ITALY

    This allows the Continuum ignitor to function without additional pilot gas which is very valuable for facilities with limited pilot gas, or for those that desire to reduce the costs or the emissions from pilot gas usage. The Continuum is commonly used in "Reduced Flaring" or "Zero Emissions" ...

  • based in ITALY

    The Sentinel flame monitor reliably provides remote flame detection up to 550 feet away, durability, ease of maintenance and rapid response time. If the monitor detects the absence of a flame for an adjustable amount of time, a set of dry form C contacts are activated and the pilot re-ignition system is set into motion. Response times are markedly quicker than those of a standard thermocouple ...

  • based in ITALY

    Hydrogen sulfide or H2S is a lethal gas generated in refineries, petrochemical plants, and gas handling facilities. Sulfur recovery units produce tail gases that contain relatively substantial amounts of H2S. AEREON designs a special type of incinerator, designed to eliminate the H2S components, while inhibiting the creation of corrosive acid by-products. Systems of this nature typically include ...

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you