Teksan

Teksan

- Model TJ9PE5C - Diesel Generator Sets

From

0

The maximum power which a generatingset is capable of delivering continuouslywhilst supplying a constant electrical load.Average load can be 100%. Thegenerator must not be overloaded.The max power available during avariable electrical power sequence,under the stated operating conditions, forwhich a generating set is capable ofdelivering in the event of a utility poweroutage or under test conditions for up to200 hrs of operation per year underaverage of 70% load. Overloading isn’tpermissible.The maximum power which a generatingset is capable of delivering continuouslywhilst supplying a variable electrical load.Average load should be 70%. Thegenerator can be overloaded 10% for 1hour per 12 hrs.

Equipment

Standard Equipments

Engine
In Teksan generator sets, leading engine brands that have state of the art technology and have compliance with ISO 8528, ISO 3046, BS 5514, DIN 6271 standarts, are being used. These engines with low fuel consumption, provide accurate speed setting and order, mount to the fuel pump, also have mechanic or electronic type governors.

Alternator
In products Teksan produced, leading alternator brands of the world that have state of the art technology, high quality, productivity and durability, are being used. All alternators, which pass necessary test process and found appropriate according to EC 60034-1; CEI EN 60034-1; BS 4999-5000; VDE 0530, NF 51- 100,111; OVE M-10, NEMA MG 1.22. standarts, have bearing system that does not need maintenance, with electronic type voltage regulator providing voltage setting.

Control Panel
Standard control panel, that is used in Teksan generator sets, ensures comfortable and safe usage. All measured and statistical parameters, operating modes, notice and alarms and condition of generator, are monitored easily from the control panel. On the front of the panel’s metal body has electronic control module and the emergency stop button and the panel’s metal body is made of steel sheet and is painted with electrostatic powder paint.

Teksan offers panel design and solutions that comply with special requirements of customers as well as quality standard panels.

Chassis and Fuel Tank
Chassis is manufactured from steel that has features and durability for carrying burden of generator set. Thanks to its rigid structural design and anti-vibration mounts, it reduces vibration level to minimum. All chassis contain lifting lugs. Apart from chassises that are produce by Teksan, special solutions that design in accordance with customer desires, make transportation and positioning easier.

In less than 1600 kVA power generator sets, fuel tank is produced integratedly to the chassis. In more than 1600 kVA power generator sets, rectangular type fuel tank is provided with generator set seperately. In all types of fuel tank have its level and indicator.

Cooling System
System, that consists of quality industrial - type radiator, expansion tank and cooler fan, keeps the temprature of generator set’s equipments constant at a proper level.

Canopy Features

TEKSAN Standard Canopies' default features are as follows;

  • Compatible with 2000/14/EC directives, certified noise emission level,
  • 2 or 4 points transport possibility according to cabin size,
  • Hidden exhaust inside the canopy,
  • Emergency stop button located on the canopy,
  • Improved air suction channel to ensure homogenous cooling in the canopy,
  • Radiator air outlet and exhaust with designed towards above,
  • Lid on cab that provides to be filled up water and antifreeze easily to the radiator,
  • Amplified paint system against corrosion and rust,
  • Improved performance in terms of sound insulation,
  • Demounted parts that make transportation and maintenance easier,

As well as the standard range of canopies, TEKSAN can also design tailormade canopies with specific sound level or size upon customer requests.

Optional Equipments

Some Optional Equipments that Teksan provides with Generator Sets;

  • Medium voltage alternator,
  • Remote radiator applications,
  • Automatic fuel filling system,
  • Fuel tank, oil pan, dashboard, alternator, coil heaters,
  • Alternator with double AVR and PMG,
  • Synchronization systems,
  • The generator output breaker,
  • Grid-generator transfer switches,
  • Accordance with the specific volume of demand-insulated cabins,
  • Seismic solutions,
  • Trailer,
  • Remote monitoring.

Control Panel Features-TJ 509-T

  • The TJ-509T is a next generation genset control unit combining multi-functionality and wide communication possibilities together with a reliable and low cost design.
  • The unit complies and mostly exceeds world’s tightest safety, EMC, vibration and environmental standards for the industrial category.
  • Software features are complete with easy firmware upgrade process through USB port. The Windows based PC software allows monitoring and programming through USB, RS-485, Ethernet and GPRS.
  • The PC and server based Rainbow Scada software allows monitoring and control of an unlimited number of gensets from a single central location.

Functions

  • AMF unit with uninterrupted transfer
  • ATS unit with uninterrupted transfer
  • Remote start controller
  • Manual start controller
  • Engine controller
  • Remote display & control unit
  • Waveform display of V & I
  • Harmonic analysis of V & I
  • CTs at genset or load side

Communications

  • SM-GPRS
  • Web monitoring
  • Web programming
  • GSM-SMS
  • e-mail
  • USB Device
  • RS-232
  • J1939-CANBUS

Topologies

  • 2 phase 3 wires, L1-L2
  • 2 phase 3 wires, L1-L3
  • 3 phase 3 wires, 3 CTs
  • 3 phase 3 wires, 2 CTs (L1-L2)
  • 3 phase 3 wires, 2 CTs (L1-L3)
  • 3 phase 4 wires, star
  • 3 phase 4 wires, delta
  • 1 phase 2 wires

Customer reviews